ExternalBuildingProtection : public <<ACC>> class
Created: 06.07.2011 15:17:10
Modified: 12.10.2012 15:26:51
Project:
Advanced:
Attribute Details
public Code
  FireProtectionClass
<<BCC>>Range:0 to 1definition=The code specifying the fire protection class of this external building protection.
dictionaryEntryName=External Building Protection. Fire Protection Class. Code
sequencingKey=1
uniqueIdentifier=UN00004052
versionIdentifier=1.0
 
public Code
  HydrantType
<<BCC>>Range:0 to 1definition=The code specifying the type of hydrant or water source, such as standard hydrant, standpipe, pond or tanker, that provides external building protection.
dictionaryEntryName=External Building Protection. Hydrant Type. Code
sequencingKey=5
uniqueIdentifier=UN00004056
versionIdentifier=1.0
 
public Text
  HydrantTypeDescription
<<BCC>>Range:0 to 1definition=The textual description of the type of hydrant that provides external building protection.
dictionaryEntryName=External Building Protection. Hydrant Type Description. Text
sequencingKey=6
uniqueIdentifier=UN00004057
versionIdentifier=1.0
 
public Measure
  NearestFireStationDistance
<<BCC>>Range:0 to 1definition=The measure of the distance from the building to the nearest fire station that provides external building protection.
dictionaryEntryName=External Building Protection. Nearest Fire Station Distance. Measure
sequencingKey=4
uniqueIdentifier=UN00004055
versionIdentifier=1.0
 
public Measure
  NearestHydrantDistance
<<BCC>>Range:0 to 1definition=The measure of the distance from the building to the nearest hydrant that provides external building protection.
dictionaryEntryName=External Building Protection. Nearest Hydrant Distance. Measure
sequencingKey=7
uniqueIdentifier=UN00004058
versionIdentifier=1.0
 
public Measure
  NearestPoliceStationDistance
<<BCC>>Range:0 to 1definition=The measure of the distance from the building to the nearest police station that provides external building protection.
dictionaryEntryName=External Building Protection. Nearest Police Station Distance. Measure
sequencingKey=8
uniqueIdentifier=UN00004059
versionIdentifier=1.0
 
public Text
  PrivateFireStationName
<<BCC>>Range:0 to 1definition=The name, expressed as text, of the private fire station that provides external building protection.
dictionaryEntryName=External Building Protection. Private Fire Station Name. Text
sequencingKey=3
uniqueIdentifier=UN00004054
versionIdentifier=1.0
 
public Text
  PublicFireStationName
<<BCC>>Range:0 to 1definition=The name, expressed as text, of the public fire station that provides external building protection.
dictionaryEntryName=External Building Protection. Public Fire Station Name. Text
sequencingKey=2
uniqueIdentifier=UN00004053
versionIdentifier=1.0
 
Element Source Role Target Role Details
«ACC» BuildingInsuranceFactor
Class «ASCC»
Name:  
 
Name: Specified
 
 
Tag Value Details
definition The protection, by external means, that a building has against a threat, such as fire.  
dictionaryEntryName ExternalBuildingProtection. Details  
uniqueIdentifier UN00004051  
versionIdentifier 1.0